Pulling around 200W on average.
- 100W for the server. Xeon E3-1231v3 with 8 spinning disks + HBA, couple of sata SSD’s
- ~80W for the unifi PoE 48 Pro switch. Most of this is PoE power for half a dozen cameras, downstream switches and AP’s, and a couple of raspberry pi’s
- ~20W for protectli vault running Opnsense
- Total usage measured via Eaton UPS
- Subsidised during the day with solar power (Enphase)
- Tracked in home assistant
You mention frigate specifically. Were you running this on the system when the drive failed, or is this a future endeavour?
I bring this up because I also use frigate, and for some time I was running with a misconfigured docker compose that drove my SSD wearout to 40% in a matter of months.
Make sure that the tmpfs is configured per the frigate documentation and example config. If misconfigured like mine was, all of that IO is on disk. I believe the ramdisk is used for temp storage of camera streams, until an event occurs and the corresponding clip is committed to disk.
Good luck!